loading

Shenmao Capacitors specialized in aluminum electrolytic capacitors from 1970.

Electrolytic capacitor installation and maintenance of small knowledge

Electrolytic capacitor after installation should pay attention to the points ( 1) Don't direct contact with the hand capacitor is negative. ( 2) Don't use sub conductor between is negative, nor on the capacitor or near the splash and conductive liquid, such as acid and alkali solution. ( 3) Please make sure the capacitor is not installed in the state of the following conditions: (1) direct contact with water, high temperature and high humidity or condensation environment easily. (2) direct contact with oil or full of oil mist. (3) direct contact with salt water, high temperature and high humidity or condensation environment. (4) with hydrochloric acid organic gases ( Such as hydrogen sulfide, sulfurous acid, nitrous acid, chlorine, bromine, methyl bromide, etc. ) In the environment. (5) of toxic alkaline will gas ( Such as ammonia, etc. ) In the environment. 6. Direct contact with acidic or alkaline solvent environment. All landowners condensation conditions could lead to a hose shrinkage, expansion, rupture, so when use please fully validated. In addition, due to the rapid changes in temperature, high temperature and high humidity test and condensation, may also lead to the same hose. Maintenance and inspection regularly, please install capacitors on industrial equipment, inspection items are as follows: ( 1) Appearance: obvious flaws, such as explosion-proof valve open, leakage, etc. ( 2) Performance: electric capacity, loss tangent, leakage current, etc. , please see the specifications in this catalog details. An emergency ( 1) Such as smoke saw the explosion-proof valve opened, immediately turn off the main switch or pull the plug. ( 2) Don't face to the valve, because when the valve opens, there will be more than 100 ℃ of gas jet. If the gas into eyes, rinse with water immediately eyes; If the suction gas, shall be immediately rinse the mouth and throat. ( 3) Don't eat the electrolyte. If the skin with the electrolyte, please wash with soap and water. Storage ( 1) Do not use capacitor stored in high temperature and high humidity. Storage condition should be followed: temperature: + 5 ℃ ~ + 35 ℃ relative humidity: < 75% storage place: indoor ( 2) Avoid storing in a environment with water, salt water or oil. ( 3) Avoid storing in toxic gases ( Such as hydrogen sulfide, sulfurous acid, nitrous acid, chlorine and ammonia, etc. ) In the environment. ( 4) Avoiding capacitor contact ozone, ultraviolet radiation, or radiation. ( 5) As far as possible keep the capacitor in the original sealed in the bag. The disposal of ( 1) Please deal with capacitor with any of the following methods: (1) hole on the shell of capacitor or complete collapse after a break in the fire burned down, With temperature of 800 ℃ or higher) 。 (2) capacitors should not be burnt, to industrial waste for landfill disposal. ( 2) When abandoned capacitor or removed from the circuit board, the production process without the use of ozone-depleting substances.

Everyone who has a electrolytic capacitor suppliers wants it to look electrolytic capacitor suppliers. However, in order to achieve that, it normally involves investing in a electrolytic capacitor suppliers electrolytic capacitor. Shenzhen Shen MaoXin Electronics Co., Ltd. can offer you the best solution.

Shenzhen Shen MaoXin Electronics Co., Ltd. will be familiar with the transformation from a generalist into a manufacturer, and will have the big-picture perspective necessary to stay focused on long-term goals.

Using high-quality materials to produce electrolytic capacitor is one of the most important part during manufacturing.

More than half of customers said they have faith with Shenzhen Shen MaoXin Electronics Co., Ltd. and electrolytic capacitor.

GET IN TOUCH WITH Us
recommended articles
News
The core of power electronic technology is the conversion and control of electric energy.
In the field of semiconductors, what China needs to challenge is the industrial system accumulated in the West for hundreds of years.
Lead-free electronic components With the continuous improvement of environmental protection awareness, people are paying more and more attention to the environmental pollution of lead and the damage to human health.
The Indonesia International Consumer Electronics Show (ICEE·Indonesia 2018) was grandly opened at the Jakarta Convention Center in Indonesia.
In order to ensure the quality of components, my country has formulated a series of component standards.
More industry information can be found at www.transmission system has undergone tremendous changes in the era of new energy vehicles.
2017 National Day holiday notice Dear customers and friends: Hello! The National Day is coming soon.
Dear old and new customers: Thank you for your continuous support and love to our company, allowing us to move forward and develop steadily.
Integrated circuit failure analysis steps: 1.

Contact Person: Mr.Michael Seung
Mobile: 0086-18923870923
michael.seung@shenmaoec.com
www.shenmaoec.net 

Contact us for better product and solution

Dedicated to helping clients solve their most challenging?products?and technology issues.

Copyright © 1970 Shenzhen Shen MaoXin Electronics Co., Ltd. | Sitemap | Privacy Policy
Customer service