How is the life of a capacitor calculated|Focus on mid-to-high-end brand capacitor manufacturers

The life of a capacitor refers to the time that the capacitor can be used when it is running. For example, when the supplier provides the capacitor, the specification parameter of the capacitor will be given. One item during the parameter period is the service life, some are 5000 hours, some are 1000 Some are tens of thousands of hours. The longer the life of the capacitor is, the better the quality of the capacitor. Then how does this test the life of the capacitor? 1. Oven Test Capacitor Life After a capacitor is developed and produced, it needs to pass a life test experiment, which is carried out in the operating state of the capacitor at the highest temperature. The upper limit of the operating temperature of some capacitors is 105° or 85° , 70° and so on. According to this upper limit, the operation is carried out in the oven. So far, the data has begun to show deviations. The deviation here refers to the error value of the capacity, which means that a safety margin will be given when the capacitance is made. For example, the upper limit of capacitor capacity is 5% and the lower limit is 5%. As long as this value is exceeded, the capacity of the capacitor will become unstable and affect the use. That is to say, when the capacity deviation occurs, the service life of the capacitor can be calculated. The formula is as follows: 2. In addition to testing the life of the capacitor, the failure point of the capacitor also requires the test to pass the test. For quality assessment, what are the failure points of capacitors, such as common capacitor breakdown, low melting point of capacitors, distortion of capacitors, abnormal noise of capacitors, etc. These are all necessary to investigate clearly. Without these steps, it may be directly after the life of the test. Supply to customers, the customer just installed the machine, the capacitor suddenly burst or the capacitor is directly broken down, then the service life problem directly rises to the product quality problem, so not only how to calculate the life of the capacitor, but also to get it Know how to locate the fault point of the capacitor. 3. Test again here refers to those relatively large manufacturing companies. It is best to test again with equipment support, because the test report provided by the supplier is the data filled in by the manufacturer itself. If the data is If there is fraud, it will bring endless hidden dangers. The best way is to not rush to install the production after getting the capacitor from the supplier. It is best to test it again internally. If the test result is provided by the supplier If the test results are consistent with more than 92%, there is basically no problem, so even if the life of the capacitor is tested, it is best to verify it by yourself and it will be foolproof.

It isn't just about being on electrolytic capacitor anymore–it's about maximizing the potential of the platform of manufacturing.

Visit Shenzhen Shen MaoXin Electronics Co., Ltd. in China for professional electrolytic capacitor tips and qulity ensured . The company is a licensed, bonded, and insured provider with decades of experience. Make your enquiry, today.

Diversifying is an excellent growth strategy, as it allows Shenmao to have multiple streams of income that can often fill seasonal voids and, of course, increase sales and profit margins.

GET IN TOUCH WITH Us
recommended articles
News
The core of power electronic technology is the conversion and control of electric energy.
In the field of semiconductors, what China needs to challenge is the industrial system accumulated in the West for hundreds of years.
Lead-free electronic components With the continuous improvement of environmental protection awareness, people are paying more and more attention to the environmental pollution of lead and the damage to human health.
The Indonesia International Consumer Electronics Show (ICEE·Indonesia 2018) was grandly opened at the Jakarta Convention Center in Indonesia.
In order to ensure the quality of components, my country has formulated a series of component standards.
More industry information can be found at www.transmission system has undergone tremendous changes in the era of new energy vehicles.
2017 National Day holiday notice Dear customers and friends: Hello! The National Day is coming soon.
Dear old and new customers: Thank you for your continuous support and love to our company, allowing us to move forward and develop steadily.
Integrated circuit failure analysis steps: 1.

Contact Person: Mr.Michael Seung
Mobile: 0086-18923870923
michael.seung@shenmaoec.com
www.shenmaoec.net 

Contact us for better product and solution

Dedicated to helping clients solve their most challenging?products?and technology issues.

Copyright © 1970 Shenzhen Shen MaoXin Electronics Co., Ltd. | Sitemap | Privacy Policy
Product Lives
Customer service